has been successfully
sent
Our specialists will contact you as soon as possible.
Materials science, mineralogy, physics and chemistry of semiconductors, microbiology and biomedicine, organic chemistry, pharmacology, pharmacy and other domains of modern science research.
* Modular design
* Easy to use
* Upright optical microscope
* High-resolution color microscope camera with a large field of view, 1’’
* Spectrograph with a focal length 284mm. or 522mm. with 4 gratings 300 lines./mm; 600 lines./mm.; 1200 lines./mm.; 1800 lines./mm.
* High-sensitivity cooled CCD camera for spectral studies
* Motorised XY-plate for standard supply set (optional piezo-plate)
* 2D Raman mapping
* Wide selection of DPSS lasers: 522 nm., 633 nm., 785 nm. and others
|
Type |
Upright optical microscope |
|
Illuminator |
Brightfield illuminator for reflected-light operation, featuring an LED light source and manual switching between "sample observation" and "spectrum acquisition" modes. |
|
Lenses |
100ˣ/50ˣ/20ˣ/10ˣ/5ˣ with a parfocal distance of 60 mm. |
|
Motorized XY plate |
Travel range: 100 x 100 mm, with a positioning accuracy of ±1.0 µm. |
|
Manual Z-plate |
Focusing unit with a travel range of 50 mm. |
|
Microscope camera |
High-resolution 9 MP color camera with a large 1" (11.3 x 11.3 mm) field of view and USB 3.0 interface. |
|
Dimensions (LxWxH), mm |
540x337x460 |
|
Weight, kg. |
30 |
Czerny-Turner spectrographs with four diffraction gratings
|
Focal length, mm |
284 |
522 |
|
|
Spectral accuracy |
± 1,0 pixel CCD |
||
|
Dispersion** (сm-1/pixel) for grating 300 lines./mm |
≈10,6 |
≈5,4 |
|
|
Dispersion ** (сm-1/pixel) grating 600 lines./mm |
≈5,2 |
≈2,6 |
|
|
Dispersion ** (сm-1/pixel) grating 1200 lines./mm |
≈2,4 |
≈1,2 |
|
|
Dispersion ** (сm-1/pixel) grating 1800 lines./mm |
≈1,4 |
≈0,7 |
|
|
Dimensions (LxWxH), mm |
410x252x214 |
555x405x290 |
|
|
Weight, kg. |
24 |
35 |
|
* For the CCD camera: pixel size 26 µm.
**λ = 546 nm, CCD camera pixel size 26 μm**
|
Module’s description: |
Single-laser module with fiber input/output |
|
Line filters: |
Up to two laser line cleaning filters |
|
Edge filters: |
Two edge filters (standard: long-pass) |
|
Fiber optics: |
Optical fiber with a diameter of 100 µm or 50 µm |
|
Dimensions (LxWxH), mm |
177x70x225 |
|
Weight, kg. |
3,2 |
|
Excitation lasers: |
Standard configuration: 532 nm, 50 mW DPSS laser; 633 nm, 785 nm, Other lasers are also available upon request. |
|
Attenuator: |
Two filter turrets 0.3; 0.6; 1.0; 1.3; 2.0; 3.0 |
|
Dimensions (LxWxH), mm |
385x90x114 |
|
Weight, kg. |
3.5 |
*** Technical specifications are subject to change and modification, based on requirements and in coordination with the customer/user.
Main window interface of the controll software SolarLS.LAB-R
|
|
|
Raman spectrum intensity color map fragment, of integrated circuit topology) |
Fragment of integrated circuit topology. |